Difference between revisions of "Masticationpedia:Sponsor"

m (1 revision imported)
m (6 revisions imported)
 
(4 intermediate revisions by one other user not shown)
Line 1: Line 1:
<languages />
{{Subhead}}
{{Subhead}}
On its platform, [[The Charity]]'s policy does not allow the presence of advertisements or banners. It nevertheless favours '''ethical sponsorship''', based on the criteria of honesty and '''practical usefulness for the user''' of the information transmitted, which are described below.
<translate><!--T:1--> On its platform, [[The Charity]]'s policy does not allow the presence of advertisements or banners. It nevertheless favours '''ethical sponsorship''', based on the criteria of honesty and '''practical usefulness for the user''' of the information transmitted, which are described below.</translate>
 
<translate><!--T:2--> In the contents of Masticationpedia, materials and procedures often mention the ''name of the manufacturer or owner'' along with their ''registered offices'' as is customarily done in international scientific journals. In Masticationpedia, however, these industrial references can be sponsored by the manufacturing industries and, therefore, will be represented in hypertext to lead the reader to the manufacturer’s website.</translate>


In the contents of Masticationpedia, materials and procedures often mention the ''name of the manufacturer or owner'' along with their ''registered offices'' as is customarily done in international scientific journals. In Masticationpedia, however, these industrial references can be sponsored by the manufacturing industries and, therefore, will be represented in hypertext to lead the reader to the manufacturer’s website.
<translate><!--T:3--> Hyper-textual links to the manufacturer will not be activated at the sponsor’s request, as it will only be inserted during editorial processing, without any commitment from the industry or institution. The interested party is, therefore, left free to consider a donation or sponsorship to the Masticationpedia project.</translate>


Hyper-textual links to the manufacturer will not be activated at the sponsor’s request, as it will only be inserted during editorial processing, without any commitment from the industry or institution. The interested party is, therefore, left free to consider a donation or sponsorship to the Masticationpedia project.
<translate><!--T:4--> How does it work in practice? We have summarized three examples in which the links we are talking about are highlighted on a yellow background (only for these examples).</translate>
How does it work in practice? We have summarized three examples in which the links we are talking about are highlighted on a yellow background (only for these examples).


__TOC__
__TOC__
<div style="display:block; padding-left: 4.5em; padding-right: 4.5em">
<div style="display:block; padding-left: 4.5em; padding-right: 4.5em">
==Example 1==
==<translate><!--T:5--> Example</translate> 1==


;''(Text in image captions)''
;''(<translate><!--T:6--> Text in image captions</translate>)''


[[File:Open bite Jaw jerk.jpg|thumb|'''Figura 1:''' Tracciato elettromiografico del jaw jerk sui masseteri. ''<span style="background-color:yellow">[http://www.ebneuro.com/it/ (Nemus2, NGF; EBNeuro, Firenze, Italy)]</span>''|left|150px]]<div style="display:block; width:100%; padding:3em; letter-spacing:1px ">
[[File:Open bite Jaw jerk.jpg|thumb|'''<translate><!--T:7--> Figure</translate> 1:''' Tracciato elettromiografico del jaw jerk sui masseteri. ''<span style="background-color:yellow">[http://www.ebneuro.com/it/ (Nemus2, NGF; EBNeuro, Firenze, Italy)]</span>''|left|150px]]<div style="display:block; width:100%; padding:3em; letter-spacing:1px ">
Nihon Koden Tokyo, Japan
Nihon Koden Tokyo, Japan
Although the piezoelectric-triggered hammer in use for the mandibular reflex does not provide controlled reproducibility and a quantification of the stimulus intensity, simultaneous recordings of the two sides are considered an essential method for the accurate and acceptable evaluation of the side asymmetry as can be seen in Fig.1 which represents an EMG trace of the jaw jerk (Nemus2 NGF, EB Neuro, Firenze, Italy) recorded on the right (upper trace) and left (lower trace) masseters. The latency asymmetry is very small, ranging from 0 to 1 ms with an average of 0.13 ms (SD 0.17) in 131 normal subjects. Although jaw jerk may be delayed by several milliseconds in trigeminal neuropathy or multiple sclerosis, latency asymmetries of only 0.8 ms were considered as an upper normal limit in neurological studies. (Figure 1).
<translate><!--T:8--> Although the piezoelectric-triggered hammer in use for the mandibular reflex does not provide controlled reproducibility and a quantification of the stimulus intensity, simultaneous recordings of the two sides are considered an essential method for the accurate and acceptable evaluation of the side asymmetry as can be seen in Fig.1 which represents an EMG trace of the jaw jerk (Nemus2 NGF, EB Neuro, Firenze, Italy) recorded on the right (upper trace) and left (lower trace) masseters. The latency asymmetry is very small, ranging from 0 to 1 ms with an average of 0.13 ms (SD 0.17) in 131 normal subjects. Although jaw jerk may be delayed by several milliseconds in trigeminal neuropathy or multiple sclerosis, latency asymmetries of only 0.8 ms were considered as an upper normal limit in neurological studies. (Figure 1).</translate>
</div>
</div>
<div style="clear: both"></div>
<div style="clear: both"></div>


==Example 2==
==<translate><!--T:9--> Example</translate> 2==


;''(Plain text)''
;''(<translate><!--T:10--> Plain text</translate>)''
<div style="display:block; width:100%; padding:3em; letter-spacing:1px ">[[File:CR MIR masseter inhibitory recovery cycle reflex.jpg|link=https://it.masticationpedia.org/index.php/File:CR_MIR.jpg|thumb|150px|'''Figure 2: Electromyographic tracing of the Masseterino Recovery Cycle ''' performed with <span style="background-color:yellow">[https://www.nihonkohden.com/index.html Nihon Koden instrumentation, Tokio, Japan]</span>]]Representation of the recovery cycle of the masseter inhibitory reflex. Note the pair of electrical stimuli (S1 and S2) and the corresponding silent periods ((ES<sub>1</sub> and ES<sub>2</sub>)) in Fig.2 of the EMG trace performed with Nihon Koden instrumentation.
<div style="display:block; width:100%; padding:3em; letter-spacing:1px ">[[File:CR MIR masseter inhibitory recovery cycle reflex.jpg|link=https://it.masticationpedia.org/index.php/File:CR_MIR.jpg|thumb|150px|'''<translate><!--T:11--> Figure</translate> 2: Electromyographic tracing of the Masseterino Recovery Cycle ''' performed with <span style="background-color:yellow">[https://www.nihonkohden.com/index.html Nihon Koden instrumentation, Tokio, Japan]</span>]]Representation of the recovery cycle of the masseter inhibitory reflex. Note the pair of electrical stimuli (S1 and S2) and the corresponding silent periods ((ES<sub>1</sub> and ES<sub>2</sub>)) in Fig.2 of the EMG trace performed with <span style="background-color:yellow">[https://www.nihonkohden.com/index.html Nihon Koden]</span> instrumentation.
</div>
</div>
<div style="clear: both"></div>
<div style="clear: both"></div>


==Example 3==
==<translate><!--T:12--> Example</translate> 3==


;''(Caption)''
;''(<translate><!--T:13--> Caption</translate>)''


[[File:Zirkozahn1.jpg|left|thumb|'''Figure 3:''' Alignment carried out with the CAD / CAM Zirkonzahn <span style="background-color:yellow">[https://www.zirkonzahn.com/ Zirkonzahn system]</span>]]
[[File:Zirkozahn1.jpg|left|thumb|'''<translate><!--T:14--> Figure</translate> 3:''' Alignment carried out with the CAD / CAM Zirkonzahn <span style="background-color:yellow">[https://www.zirkonzahn.com/ Zirkonzahn system]</span>]]
<div style="display:block; width:100%; padding:3em; letter-spacing:1px ">
<div style="display:block; width:100%; padding:3em; letter-spacing:1px ">


On the site, you can find references to dental instruments as in the case in which the online update refers to CAD / CAM systems. Beyond the certifications and/or reassurances of precision, resolution and more, during our professional life we have witnessed a series of bioengineering errors which a colleague, who is not very attentive to the technologies and the genesis of bioengineering phenomena, can overlook while at Masticationpedia, established by researchers, mathematicians, or engineers, it hardly goes unnoticed. For this reason, for each article and topic considered, both the editorial content and the discussion will appear in addition to the hypertext reference to the manufacturer. (Figure 3)</div>
<translate><!--T:15--> On the site, you can find references to dental instruments as in the case in which the online update refers to CAD / CAM systems. Beyond the certifications and/or reassurances of precision, resolution and more, during our professional life we have witnessed a series of bioengineering errors which a colleague, who is not very attentive to the technologies and the genesis of bioengineering phenomena, can overlook while at Masticationpedia, established by researchers, mathematicians, or engineers, it hardly goes unnoticed. For this reason, for each article and topic considered, both the editorial content and the discussion will appear in addition to the hypertext reference to the manufacturer.</translate> (<translate><!--T:16--> Figure</translate> 3)</div>
</div>
</div>
<div style="clear: both"></div>
<div style="clear: both"></div>


==Do you want to support us with an ethical sponsorship?==
==<translate><!--T:17--> Do you want to support us with an ethical sponsorship?</translate>==
   
   
Write to info{{@}}masticationpedia.org to receive all the information in this regard.
<translate><!--T:18--> Write us at info{{@}}masticationpedia.org to receive all the information in this regard.</translate>


{{apm}}
[[Category:Masticationpedia]]
[[Category:Masticationpedia]]
[[it:Masticationpedia:Sponsor]]

Latest revision as of 22:04, 13 February 2022



On its platform, The Charity's policy does not allow the presence of advertisements or banners. It nevertheless favours ethical sponsorship, based on the criteria of honesty and practical usefulness for the user of the information transmitted, which are described below.

In the contents of Masticationpedia, materials and procedures often mention the name of the manufacturer or owner along with their registered offices as is customarily done in international scientific journals. In Masticationpedia, however, these industrial references can be sponsored by the manufacturing industries and, therefore, will be represented in hypertext to lead the reader to the manufacturer’s website.

Hyper-textual links to the manufacturer will not be activated at the sponsor’s request, as it will only be inserted during editorial processing, without any commitment from the industry or institution. The interested party is, therefore, left free to consider a donation or sponsorship to the Masticationpedia project.

How does it work in practice? We have summarized three examples in which the links we are talking about are highlighted on a yellow background (only for these examples).

Example 1

(Text in image captions)
Figure 1: Tracciato elettromiografico del jaw jerk sui masseteri. (Nemus2, NGF; EBNeuro, Firenze, Italy)

Nihon Koden Tokyo, Japan Although the piezoelectric-triggered hammer in use for the mandibular reflex does not provide controlled reproducibility and a quantification of the stimulus intensity, simultaneous recordings of the two sides are considered an essential method for the accurate and acceptable evaluation of the side asymmetry as can be seen in Fig.1 which represents an EMG trace of the jaw jerk (Nemus2 NGF, EB Neuro, Firenze, Italy) recorded on the right (upper trace) and left (lower trace) masseters. The latency asymmetry is very small, ranging from 0 to 1 ms with an average of 0.13 ms (SD 0.17) in 131 normal subjects. Although jaw jerk may be delayed by several milliseconds in trigeminal neuropathy or multiple sclerosis, latency asymmetries of only 0.8 ms were considered as an upper normal limit in neurological studies. (Figure 1).

Example 2

(Plain text)
Figure 2: Electromyographic tracing of the Masseterino Recovery Cycle performed with Nihon Koden instrumentation, Tokio, Japan
Representation of the recovery cycle of the masseter inhibitory reflex. Note the pair of electrical stimuli (S1 and S2) and the corresponding silent periods ((ES1 and ES2)) in Fig.2 of the EMG trace performed with Nihon Koden instrumentation.

Example 3

(Caption)
Figure 3: Alignment carried out with the CAD / CAM Zirkonzahn Zirkonzahn system
On the site, you can find references to dental instruments as in the case in which the online update refers to CAD / CAM systems. Beyond the certifications and/or reassurances of precision, resolution and more, during our professional life we have witnessed a series of bioengineering errors which a colleague, who is not very attentive to the technologies and the genesis of bioengineering phenomena, can overlook while at Masticationpedia, established by researchers, mathematicians, or engineers, it hardly goes unnoticed. For this reason, for each article and topic considered, both the editorial content and the discussion will appear in addition to the hypertext reference to the manufacturer. (Figure 3)

Do you want to support us with an ethical sponsorship?

Write us at info@masticationpedia.org to receive all the information in this regard.

Wiki.png