Difference between revisions of "Transverse Hinge Axis"

Line 24: Line 24:
The choice of using <math>P_c</math> or <math>O_c</math> can generate a significant error, with an angular variation of <math>8.51^\circ</math>, which can reach up to <math>10^\circ</math>, as indicated by Oliver Schierz et al.<ref>[https://www.researchgate.net/profile/Oliver-Schierz/publication/319390817_Impact_of_mounting_methods_in_computerized_axiography_on_assessment_of_condylar_inclination/links/5ecfad1992851c9c5e63ba15/Impact-of-mounting-methods-in-computerized-axiography-on-assessment-of-condylar-inclination.pdf?origin=publicationDetail&_sg%5B0%5D=5gcZcMPe-o4_Pl6wkh2xujLIHsSjxIskFKb2rDTsy5LK5G_iE-MroMtkjg0O9gUHRBkjnYu5GTqV-fxPRuinww.XRi95a2o7EJ4r8p3CoKKbPn6ghsFjZ4Jr3JU30vq9Uzz_e34x4HMd2fd9xEt4SGZWuK88KfPaaSfAINagYBlMA&_sg%5B1%5D=P6dZ5Xgw8ZYwG8EW4imuRv2P_BjeMIsu711me70-6nx-0D-yjv4t34n8KnBn_ciDfa5km_cLb0t_AhxuDKiNtTTwZOB2W7nuktpkvFGBvMJG.XRi95a2o7EJ4r8p3CoKKbPn6ghsFjZ4Jr3JU30vq9Uzz_e34x4HMd2fd9xEt4SGZWuK88KfPaaSfAINagYBlMA&_iepl=&_rtd=eyJjb250ZW50SW50ZW50IjoibWFpbkl0ZW0ifQ%3D%3D&_tp=eyJjb250ZXh0Ijp7ImZpcnN0UGFnZSI6InB1YmxpY2F0aW9uIiwicGFnZSI6InB1YmxpY2F0aW9uIiwicG9zaXRpb24iOiJwYWdlSGVhZGVyIn19 Oliver Schierz et al.]</ref> This error is transferred to the prosthetic phase, generating a spatial discrepancy in the cuspal position. </blockquote>
The choice of using <math>P_c</math> or <math>O_c</math> can generate a significant error, with an angular variation of <math>8.51^\circ</math>, which can reach up to <math>10^\circ</math>, as indicated by Oliver Schierz et al.<ref>[https://www.researchgate.net/profile/Oliver-Schierz/publication/319390817_Impact_of_mounting_methods_in_computerized_axiography_on_assessment_of_condylar_inclination/links/5ecfad1992851c9c5e63ba15/Impact-of-mounting-methods-in-computerized-axiography-on-assessment-of-condylar-inclination.pdf?origin=publicationDetail&_sg%5B0%5D=5gcZcMPe-o4_Pl6wkh2xujLIHsSjxIskFKb2rDTsy5LK5G_iE-MroMtkjg0O9gUHRBkjnYu5GTqV-fxPRuinww.XRi95a2o7EJ4r8p3CoKKbPn6ghsFjZ4Jr3JU30vq9Uzz_e34x4HMd2fd9xEt4SGZWuK88KfPaaSfAINagYBlMA&_sg%5B1%5D=P6dZ5Xgw8ZYwG8EW4imuRv2P_BjeMIsu711me70-6nx-0D-yjv4t34n8KnBn_ciDfa5km_cLb0t_AhxuDKiNtTTwZOB2W7nuktpkvFGBvMJG.XRi95a2o7EJ4r8p3CoKKbPn6ghsFjZ4Jr3JU30vq9Uzz_e34x4HMd2fd9xEt4SGZWuK88KfPaaSfAINagYBlMA&_iepl=&_rtd=eyJjb250ZW50SW50ZW50IjoibWFpbkl0ZW0ifQ%3D%3D&_tp=eyJjb250ZXh0Ijp7ImZpcnN0UGFnZSI6InB1YmxpY2F0aW9uIiwicGFnZSI6InB1YmxpY2F0aW9uIiwicG9zaXRpb24iOiJwYWdlSGVhZGVyIn19 Oliver Schierz et al.]</ref> This error is transferred to the prosthetic phase, generating a spatial discrepancy in the cuspal position. </blockquote>


<center> <gallery widths="350" heights="282" perrow="2" mode="slideshow"> File:Epoc-0040 copia.jpg|'''Figure 1:''' Axiography performed through occlusal spoon clutching File:Axiography 1.jpg|'''Figure 2:''' Paraocclusal spoon File:Paraocclusal Clouth 1 .jpg|'''Figure 3:''' Representation of angular discrepancies due to the use of paraocclusal <math>P_c</math> and occlusal <math>O_c</math> spoons </gallery> </center>
<center> <gallery widths="350" heights="282" perrow="2" mode="slideshow"> File:Epoc-0040 copia.jpg|'''Figure 1:''' Axiography performed through occlusal spoon clutching  
File:Axiography 1.jpg|'''Figure 2:''' Cucchiaio paraocclisale
File:Paraocclusal Clouth 1 .jpg|'''Figure 3:'''  
Representation of angular discrepancies due to the use of paraocclusal <math>P_c</math> and occlusal <math>O_c</math> spoons </gallery> </center>


==Localization Error <math>_tHA</math> from Chord <math>s</math> and Sagitta <math>h</math>==
==Localization Error <math>_tHA</math> from Chord <math>s</math> and Sagitta <math>h</math>==